It is a Class-D digital amplifier which is used for the voice signal broadcasting in EVAC system.And it is a 2U device that integrates 4 independent PFC functions, a power-saving control module, and the 120W/240W/350W/500W power amplifier with DC24V power interface, 2 channels.
	
	
* Modular design, easy to configure as required.
* The use of efficient class-D digital power amplifier design scheme has lower power consumption.
* 2U design, 2 independent channels, each channel 120W/240W/350W/500W.
* Overload, short circuit protection, automatic temperature control.
* Automatically detect the working status of each channel and indicate by LED.
* Support power saving mode, enter standby mode when there is no signal.
	
	
| 
					 Model  | 
				
					 VA-P2120  | 
				
					 VA-P2240  | 
				
					 VA-P2350  | 
				
					 VA-P2500  | 
			||||||
| 
					 AC power supply  | 
				
					 
  | 
			|||||||||
| 
					 Voltage  | 
				
					 ~ 220V 50Hz  | 
			|||||||||
| 
					 Working current  | 
				
					 1.4A  | 
				
					 2.6A  | 
				
					 4A  | 
				
					 5.5A  | 
			||||||
| 
					 DC power supply  | 
				
					 
  | 
			|||||||||
| 
					 DC input  | 
				
					 DC~24V; ±20%  | 
			|||||||||
| 
					 Working current  | 
				
					 12.3A  | 
				
					 24A  | 
				
					 35A  | 
				
					 50A  | 
			||||||
| 
					 Power  | 
				
					 2x120W  | 
				
					 2x240W  | 
				
					 2x350W  | 
				
					 2x500W  | 
			||||||
| 
					 Power Consumption  | 
				
					 295W  | 
				
					 580W  | 
				
					 845W  | 
				
					 1200W  | 
			||||||
| 
					 Audio Parameter  | 
				
					 
  | 
			|||||||||
| 
					 Input mode  | 
				
					 Balance 385mV  | 
			|||||||||
| 
					 Frequency Response  | 
				
					 40Hz-20KHz±3dB  | 
			|||||||||
| 
					 Output  | 
				
					 100V Constant Voltage  | 
			|||||||||
| 
					 THD  | 
				
					 ≤1% (Rated Power THD), 1KHz  | 
			|||||||||
| 
					 SNR  | 
				
					 ≥90dB  | 
			|||||||||
| 
					 Working Temperature  | 
				
					 5℃ ~ 40℃  | 
			|||||||||
| 
					 Relative Humidity  | 
				
					 < 95%  | 
			|||||||||
| 
					 Cooling Mode  | 
				
					 Air-Cooled  | 
			|||||||||
| 
					 Protection  | 
				
					 Delay, Short Circuit, Overload, Over-temperature  | 
			|||||||||
| 
					 Dimensions  | 
				
					 484 x 478 x 88mm (Machine feet not included)  | 
			|||||||||
| 
					 Net weight  | 
				
					 9.8Kg  | 
				
					 10.06Kg  | 
				
					 10.26Kg  | 
				
					 10.49Kg  | 
			||||||